* update scratch.md for issue #4068 Issue #4068 details the dangers of recommending single etcd instance. This will likely need to be expanded into better "highly available" cluster documentation * Refactor list style * fix ordered list * fix unordered list * ul * add back shell
This commit is contained in:
committed by
Andrew Chen
parent
787d50a1af
commit
bfdc9a64e8
@@ -444,14 +444,29 @@ because of how this is used later.
|
||||
- Alternate, manual approach:
|
||||
|
||||
1. Set `--configure-cbr0=false` on kubelet and restart.
|
||||
1. Create a bridge
|
||||
- `ip link add name cbr0 type bridge`.
|
||||
1. Create a bridge.
|
||||
|
||||
```
|
||||
ip link add name cbr0 type bridge
|
||||
```
|
||||
|
||||
1. Set appropriate MTU. NOTE: the actual value of MTU will depend on your network environment
|
||||
- `ip link set dev cbr0 mtu 1460`
|
||||
|
||||
```
|
||||
ip link set dev cbr0 mtu 1460
|
||||
```
|
||||
|
||||
1. Add the node's network to the bridge (docker will go on other side of bridge).
|
||||
- `ip addr add $NODE_X_BRIDGE_ADDR dev cbr0`
|
||||
|
||||
```
|
||||
ip addr add $NODE_X_BRIDGE_ADDR dev cbr0
|
||||
```
|
||||
|
||||
1. Turn it on
|
||||
- `ip link set dev cbr0 up`
|
||||
|
||||
```
|
||||
ip link set dev cbr0 up
|
||||
```
|
||||
|
||||
If you have turned off Docker's IP masquerading to allow pods to talk to each
|
||||
other, then you may need to do masquerading just for destination IPs outside
|
||||
@@ -501,11 +516,13 @@ all configured and managed *by Kubernetes*:
|
||||
|
||||
You will need to run one or more instances of etcd.
|
||||
|
||||
- Recommended approach: run one etcd instance, with its log written to a directory backed
|
||||
- Highly available and easy to restore - Run 3 or 5 etcd instances with, their logs written to a directory backed
|
||||
by durable storage (RAID, GCE PD)
|
||||
- Alternative: run 3 or 5 etcd instances.
|
||||
- Log can be written to non-durable storage because storage is replicated.
|
||||
- run a single apiserver which connects to one of the etcd nodes.
|
||||
- Not highly available, but easy to restore - Run one etcd instance, with its log written to a directory backed
|
||||
by durable storage (RAID, GCE PD)
|
||||
**Note:** May result in operations outages in case of instance outage
|
||||
- Highly available - Run 3 or 5 etcd instances with non durable storage.
|
||||
**Note:** Log can be written to non-durable storage because storage is replicated.
|
||||
|
||||
See [cluster-troubleshooting](/docs/admin/cluster-troubleshooting) for more discussion on factors affecting cluster
|
||||